Case example of Becker U4.100 vacuum pump maintenance.:   

Oil carbon inside of the oil tank turns black, making the oil circuit and heat cooler stuck. The pump head has lost its lubricant effect. Impeller Cylinder grinds against the rotor and results in wavy cylinder.

Front cover and bearing wear. The rotor shaft seal position is circumscribed. Excessive absorption of oil leads to clogging and smoking. Oil circuit clogging hinders the vacuum pump to run smoothly.